SMAR LD-301 Intelligent Pressure Transmitter (HART Protocol) (U01)
OPC Server Data Sheet
Devices Supported: |
Model LD-301Intelligent Pressure Transmitter with Control
Capability |
Device
Manufacturer: |
SMAR |
Profile Name: |
LD301.PRO |
Profile Built For: |
UOS |
Platform: |
Windows NT4.0 / 2000 / XP |
Interface Type: |
Serial: RS232 |
Max Devices
Supported: |
15 |
Protocol: |
HART |
Comment: |
U01 is comprised of the Universal OPC
Server (UOS) for Serial and TCP/IP Devices and the LD301.PRO device
profile. The U01 mnemonic is used to identify this unique combination. UOS will also
support many other serial or TCP/IP device profiles. Please refer to our web site for the
current list. |
|
UOS is a stand-alone OPC Server that can be used with any OPC
compliant Client such as Intellutions FIX® or FIX Dynamics® or
OAs Enterprise Automation software. UOS has many advanced features like: DataView,
DataScope, Serial and TCP/IP communications support, and multiple "different"
device support. Please refer to our web site for more information on UOS capabilities. |
Contact: |
Dimension Software, Inc.
1536 St. Clair Road, Taylorsville, NC 28681, USA
Voice: (828) 635-7189, Fax: (828) 625-5319,
E-Mail: ,
Web: http://dimension-software.com |
References: |
UOS (Universal OPC Server) Electronic
Documentation |
|
Introduction
|
This document provides general information on the device commands supported by UOS and
the LD301.PRO profile. If you have installed UOS, you should also review the sections
titled About the I/O Driver, How Do I
, Setting up The I/O Driver, and
Using the PowerTool in the UOS electronic documentation. To get there, click on Help
and Help Topics on the PowerTool menu bar. The PowerTool is a client application
with a graphical user interface that accesses the UOS OPC Server and lets you view and
modify communications channel, device, and datablock properties. |
|
Device Commands Supported
|
U01 I/O Driver supports the following device commands. Please refer to the HART
Communications Protocol, Universal Command Specifications, Revision 5.1, Document Number:
HCF-SPEC-127, pg 1 - 25 for detailed information on the universal command codes. |
|
Table 1 Supported Universal Commands for the SMAR
LD301 Pressure Transmitter using HARTSMAR.PRO Profile |
Command Code |
Description |
|
Universal Command Codes |
0 |
Read unique identifier |
1 |
Read primary variable |
2 |
Read PV current and percent of range |
3 |
Read dynamic variables and PV current |
14 |
Read primary variable sensor information |
15 |
Read primary variable output information |
16 |
Read final assembly number |
19 |
Write final assembly number |
|
Table 2 Supported Device Specific Commands for the
SMAR LD301 Pressure Transmitter using HARTSMAR.PRO Profile |
Command Code |
Description |
136 |
Read PID block configuration |
137 |
Write PID block configuration |
138 |
Read controller mode |
139 |
Write controller mode |
141 |
Write set point tracking and PID mode |
142 |
Read PID block parameters |
143 |
Write proportional factor (kp) |
144 |
Write integral time (tr) |
145 |
Write derivation time (td) |
146 |
Write set point |
147 |
Write manipulated variable (mv) |
193 |
Read controller variables |
Comment: |
This I/O Driver has the following special
features: |
|
Poll-on-Demand |
|
Enable/Disable polling for a selected device |
|
Diagnostics for each device instead of per-channel |
|
Write multiple variables simultaneously |
|
Protocol Supported: |
Protocol Type: HART |
Supported: N/A |
Baud Rates: 1200 |
Data Bits: 8 |
Stop Bits: 1 |
Parity: ODD |
Comment: The table below describes the Channel Setup settings for the
HART protocol. The settings listed in the table were used during testing at DSI. They
could vary depending on your particular application. The driver period should be set to 2.
|
|
Table 3 Channel Setup settings for the HART protocol |
Field |
Setting |
Comments |
|
Hardware Setup Area |
|
Port |
User Choice |
|
Baud Rate |
1200 |
|
Data Bits |
8 |
|
Stop Bits |
1 |
|
Parity |
Odd |
|
Flow Control |
RTS Delay |
Refer to the Pre-RTS field. |
|
RTS Delay Area |
|
Pre-Transmit |
0 |
|
Post-Transmit |
0 |
|
Pre-RTS |
100 |
The HART protocol requires a delay after sending a message to U01. 100msec
was used during testing of the HARTSMAR.PRO profile. |
|
Error Handling Area |
|
Reply Timeout |
2.0 |
|
Delay |
1.0 |
|
Retries |
3 |
|
|
Interface Modules: |
Device Manufacturer: ANSCO, PO Box 24069, Minneapolis MN 55424 |
Interface: PRIMM modem, Bell-202 modem for HART protocol, RS-232 port
powered. |
Comment: HART protocol devices such as the SMAR LD-301 Pressure
Transmitter requires a modem between the computer serial port and the device network. A
PRIMM modem manufactured by Ansco, Inc. was used during testing. |
Signal Conditioning
Name: |
Description: |
NONE |
No Scaling |
LIN (Unsigned) |
Scales 16-bit unsigned values to the database block's EGU
range. |
LIN (Signed) |
Scales 16-bit signed values to the database block's EGU
range. |
3BCD |
Scales 3-digit Binary Coded Decimal values to the database
block's EGU range. |
4BCD |
Scales 4-digit Binary Coded Decimal values to the database
block's EGU range. |
8BN |
Scales 8-bit binary values to the database block's EGU
range. Ignores the most significant byte. No Alarming on Out of Range. |
8AL |
Scales 8-bit binary values to the database block's EGU
range. Ignores the most significant byte. Alarming on Out of Range. |
12BN |
Scales 12-bit binary values to the database block's EGU
range. Ignores the most significant nibble (4-bits). No Alarming on Out of
Range. |
12AL |
Scales 12-bit binary values to the database block's EGU
range. Ignores the most significant nibble (4-bits). Alarming on Out of
Range. |
13BN |
Scales 13-bit binary values to the database block's EGU
range. Ignores the most significant 3 bits. No Alarming on Out of Range. |
13AL |
Scales 13-bit binary values to the database block's EGU
range. Ignores the most significant 3 bits. Alarming on Out of Range. |
15BN |
Scales 15-bit binary values to the database block's EGU
range. Ignores the most significant bit. No Alarming on Out of Range. |
15AL |
Scales 15-bit binary values to the database block's EGU
range. Ignores the most significant bit. Alarming on Out of Range. |
|
|