Yokogawa UT15 and UT15L Controllers (U15)
OPC Server Data Sheet

Devices Supported: Yokogawa UT15 and UT15L Controllers
Device Manufacturer: Yokogawa
Profile Name: YK_UT15L.PRO
Profile Built For: UOS
Platform: Windows NT4.0 / 2000 / XP
Interface Type: Serial: RS-422
Max Devices Supported: 16 units, excluding host
Protocol: YOKOGAWA
Comment: U15 is comprised of the Universal OPC Server (UOS) for Serial and TCP/IP Devices and the YK_UT15L.PRO device profile. The U15 mnemonic is used to identify this unique combination. UOS will also support many other serial or TCP/IP device profiles. Please refer to our web site for the current list.
UOS is a stand-alone OPC Server that can be used with any OPC compliant Client such as Intellution’s FIX® or FIX Dynamics® or OA’s Enterprise Automation software. UOS has many advanced features like: DataView, DataScope, Serial and TCP/IP communications support, and multiple "different" device support. Please refer to our web site for more information on UOS capabilities.
Contact: Dimension Software, Inc.
1536 St. Clair Road, Taylorsville, NC 28681, USA
Voice:
(828) 635-7189, Fax: (828) 625-5319, E-Mail: , Web: http://dimension-software.com
References:  UOS (Universal OPC Server) Electronic Documentation
UT15L Instruction Manual. Manual Number IM 5B4A7-11E. UT15, UM05 Communications Interface(RS-422A). Manual Number IM 5B4A7-50E
 
Introduction

This document provides general information on the device commands supported by UOS and the YK_UT15L.PRO profile. If you have installed UOS, you should also review the sections titled About the I/O Driver, How Do I…, Setting up The I/O Driver, and Using the PowerTool in the UOS electronic documentation. To get there, click on Help and Help Topics on the PowerTool menu bar. The PowerTool is a client application with a graphical user interface that accesses the UOS OPC Server and lets you view and modify communications channel, device, and datablock properties.

 
Interface Modules:
 
Device Manufacturer: Yokogawa Electric Corporation
Interface: RS-422, 4-wire
Comment: Telebyte Model 245 RS-232 to RS-422/RS-485 Interface Converter used during testing.
 
Device Commands Supported
U15 supports the following Yokogawa commands:
 
Table 1 UT15 Yokogawa Function Codes Supported
If the U15 Command Group is... Then the UT15 READ COMMAND is... Then the UT15 WRITE COMMAND is...
OPEN (Open communications with UT15) n/a O
CLOSE (Close communications with UT15) n/a C
DP (Read device settings) DP n/a
DA (Read Alarm 1, 2, 3 & 4) DA n/a
A1 (Read/Write Alarm 1 Setpoint) A1 A1
A2 (Read/Write Alarm 2 Setpoint) A2 A2
SP (Read/Write Setpoint) SP SP
RH (Read max. input range value) RH n/a
RL (Read min. input range value) RL n/a
DV (Read device address) DV n/a
HY (Read/Write Hysteresis) HY HY
BS (Read/Write Signal Bias) BS BS
 
Protocol Supported:
 
Protocol Type: YOKOGAWA
Baud Rates: 300, 1200, 2400, 4800, 9600
Data Bits: 8
Stop Bits: 1
Parity: NONE
 
Signal Conditioning:
 
Signal Conditioning Name: Description:
NONE No Scaling
LIN (Unsigned) Scales 16-bit unsigned values to the database block's EGU range.
LIN (Signed) Scales 16-bit signed values to the database block's EGU range.
3BCD Scales 3-digit Binary Coded Decimal values to the database block's EGU range.
4BCD Scales 4-digit Binary Coded Decimal values to the database block's EGU range.
8BN Scales 8-bit binary values to the database block's EGU range. Ignores the most significant byte. No Alarming on Out of Range.
8AL  Scales 8-bit binary values to the database block's EGU range. Ignores the most significant byte. Alarming on Out of Range.
12BN Scales 12-bit binary values to the database block's EGU range. Ignores the most significant nibble (4-bits). No Alarming on Out of Range.
12AL  Scales 12-bit binary values to the database block's EGU range. Ignores the most significant nibble (4-bits). Alarming on Out of Range.
13BN Scales 13-bit binary values to the database block's EGU range. Ignores the most significant 3 bits. No Alarming on Out of Range.
13AL  Scales 13-bit binary values to the database block's EGU range. Ignores the most significant 3 bits. Alarming on Out of Range.
15BN Scales 15-bit binary values to the database block's EGU range. Ignores the most significant bit. No Alarming on Out of Range.
15AL  Scales 15-bit binary values to the database block's EGU range. Ignores the most significant bit. Alarming on Out of Range.
 