Sentinel 500 Gas Orifice Flow Computer (UFC)
OPC Server Data Sheet
Devices Supported: |
Sentinel 500 Gas Orifice FlowComputer (UFC) |
Device
Manufacturer: |
Daniel Europe LTD, Swinton Grange, Malton, North Yorkshire,
Y017, United Kingdom |
Profile Name: |
UFC.PRO |
Profile Built For: |
UOS |
Platform: |
Windows NT4.0 / 2000 / XP |
Interface Type: |
RS-232 |
Baud Rates: |
9600 |
Data Bits: |
8 |
Stop Bits: |
1 |
Parity: |
EVEN |
Flow Control: |
RTS-Delay: Pre-Transmit = 0, Post-Transmit = 0,
Pre-RTS = 50 |
Max Devices
Supported: |
1 |
Protocol: |
Modbus Protocol (Modified) |
Comment: |
UFC is comprised of the Universal OPC
Server (UOS) for Serial and TCP/IP Devices and the UFC.PRO device
profile. The UFC mnemonic is used to identify this unique combination. UOS will also
support many other serial or TCP/IP device profiles. Please refer to our web site for the
current list. |
|
UOS is a stand-alone OPC Server that can be used with any OPC
compliant Client such as Intellutions FIX® or FIX Dynamics® or
OAs Enterprise Automation software. UOS has many advanced features like: DataView,
DataScope, Serial and TCP/IP communications support, and multiple "different"
device support. Please refer to our web site for more information on UOS capabilities. |
Contact: |
Dimension Software, Inc.
1536 St. Clair Road, Taylorsville, NC 28681, USA
Voice: (828) 635-7189, Fax: (828) 625-5319,
E-Mail: ,
Web: http://dimension-software.com |
References: |
UOS (Universal OPC Server) Electronic
Documentation |
|
Introduction
|
This document provides general information on the device commands supported by UOS and
the UFC.PRO profile. If you have installed UOS, you should also review the sections titled
About the I/O Driver, How Do I
, Setting up The I/O Driver, and Using the
PowerTool in the UOS electronic documentation. To get there, click on Help and Help
Topics on the PowerTool menu bar. The PowerTool is a client application with a
graphical user interface that accesses the UOS OPC Server and lets you view and modify
communications channel, device, and datablock properties.
|
|
Device Commands Supported
|
|
UFC supports the following commands: |
If the Profile Command Group is
|
Then the Device READ command is
|
And the Device WRITE command is
|
Description |
M/S_STATUS/ALM |
02 |
05 |
R Multiple W Single Alarm/Status |
M/S_NUMERIC |
03 |
10 |
R Multiple W Single Float |
Signal Conditioning
Name: |
Description: |
NONE |
No Scaling |
LIN (Unsigned) |
Scales 16-bit unsigned values to the database block's EGU
range. |
LIN (Signed) |
Scales 16-bit signed values to the database block's EGU
range. |
3BCD |
Scales 3-digit Binary Coded Decimal values to the database
block's EGU range. |
4BCD |
Scales 4-digit Binary Coded Decimal values to the database
block's EGU range. |
8BN |
Scales 8-bit binary values to the database block's EGU
range. Ignores the most significant byte. No Alarming on Out of Range. |
8AL |
Scales 8-bit binary values to the database block's EGU
range. Ignores the most significant byte. Alarming on Out of Range. |
12BN |
Scales 12-bit binary values to the database block's EGU
range. Ignores the most significant nibble (4-bits). No Alarming on Out of
Range. |
12AL |
Scales 12-bit binary values to the database block's EGU
range. Ignores the most significant nibble (4-bits). Alarming on Out of
Range. |
13BN |
Scales 13-bit binary values to the database block's EGU
range. Ignores the most significant 3 bits. No Alarming on Out of Range. |
13AL |
Scales 13-bit binary values to the database block's EGU
range. Ignores the most significant 3 bits. Alarming on Out of Range. |
15BN |
Scales 15-bit binary values to the database block's EGU
range. Ignores the most significant bit. No Alarming on Out of Range. |
15AL |
Scales 15-bit binary values to the database block's EGU
range. Ignores the most significant bit. Alarming on Out of Range. |
|
|
© 2011 Dimension Software, Inc. All Rights Reserved.
|
|
|
|
|