Daniel Flow Products, Inc. SolarFlow Plus 2480 Meter (USF)
OPC Server
Data Sheet
Devices Supported: |
SolarFlow Plus 2480 Meter |
Device Manufacturer: |
Daniel Flow Products, Inc. |
Profile Name: |
SolarFlowPlus.PRO |
Profile Built For: |
UOS |
Platform: |
Windows NT4.0 / 2000 / XP |
Interface Type: |
RS-232 |
Max Devices Supported: |
1 (Direct or Modem Connection) |
Protocol: |
Daniel Flow Products, Inc. DSI Communications Protocol for
the SolarFlow Plus |
Comment: |
USF is comprised of the Universal OPC
Server (UOS) for Serial and TCP/IP Devices and the SolarFlowPlus.PRO
device profile. The USF mnemonic is used to identify this unique combination. UOS will
also support many other serial or TCP/IP device profiles. Please refer to our web site for
the current list. |
|
UOS is a stand-alone OPC Server that can be used with any OPC
compliant Client such as Intellutions FIX® or FIX Dynamics® or
OAs Enterprise Automation software. UOS has many advanced features like: DataView,
DataScope, Serial and TCP/IP communications support, and multiple "different"
device support. Please refer to our web site for more information on UOS capabilities. |
Contact: |
Dimension Software, Inc.
1536 St. Clair Road, Taylorsville, NC 28681, USA
Voice: (828) 635-7189, Fax: (828) 625-5319,
E-Mail: ,
Web: http://dimension-software.com |
References: |
UOS (Universal OPC Server) Electronic
Documentation |
|
- Daniel Flow Products, Inc. Software Engineering, DSI
- Communications Protocol, SolarFlow Plus Rev. C (09/92)
|
|
Introduction
|
This document provides general information on the device commands supported by UOS and
the USF.PRO profile. If you have installed UOS, you should also review the sections titled
About the I/O Driver, How Do I
, Setting up The I/O Driver, and Using the
PowerTool in the UOS electronic documentation. To get there, click on Help and Help
Topics on the PowerTool menu bar. The PowerTool is a client application with a
graphical user interface that accesses the UOS OPC Server and lets you view and modify
communications channel, device, and datablock properties. |
|
Device Commands Supported
|
The device READ/WRITE commands supported are shown in Table 1. They are described in
reference to the profile command group that contains them. A "profile command
group" is a group of related commands. Usually it consists of an I/O Device
READ/WRITE command pair. However the command group can contain only a device READ command,
only a device WRITE command, or more than one device READ/WRITE pair. This depends on the
protocol of the I/O Device to which the command is directed. |
|
Table 1 - Device Commands Supported by the SolarFlowPlus.PRO Profile
|
If the Profile
Command Group is
|
Then the Device
READ command is
|
And the Device
WRITE command is
|
Description |
LogonDirect |
n/a |
n/a |
Logon procedure via Direct Connection |
LogonModem |
n/a |
n/a |
Logon procedure via Modem |
Logoff |
01h |
n/a |
Logoff |
R/WDigitalCh |
0Bh |
0Ah |
R/W Digital Channel (1-18) |
R/WAnalogCh |
0Bh |
0Ah |
R/W Analog Channel (19-89,98) |
Version |
00h |
n/a |
Retrieve Version |
RetrieveDateTime |
05h |
n/a |
Retrieve Date and Time |
ContactUnitSlave |
03h |
n/a |
Contact Unit Slave (Normally not used) |
Signal Conditioning
Name: |
Description: |
NONE |
No Scaling |
LIN (Unsigned) |
Scales 16-bit unsigned values to the database block's EGU
range. |
LIN (Signed) |
Scales 16-bit signed values to the database block's EGU
range. |
3BCD |
Scales 3-digit Binary Coded Decimal values to the database
block's EGU range. |
4BCD |
Scales 4-digit Binary Coded Decimal values to the database
block's EGU range. |
8BN |
Scales 8-bit binary values to the database block's EGU
range. Ignores the most significant byte. No Alarming on Out of Range. |
8AL |
Scales 8-bit binary values to the database block's EGU
range. Ignores the most significant byte. Alarming on Out of Range. |
12BN |
Scales 12-bit binary values to the database block's EGU
range. Ignores the most significant nibble (4-bits). No Alarming on Out of
Range. |
12AL |
Scales 12-bit binary values to the database block's EGU
range. Ignores the most significant nibble (4-bits). Alarming on Out of
Range. |
13BN |
Scales 13-bit binary values to the database block's EGU
range. Ignores the most significant 3 bits. No Alarming on Out of Range. |
13AL |
Scales 13-bit binary values to the database block's EGU
range. Ignores the most significant 3 bits. Alarming on Out of Range. |
15BN |
Scales 15-bit binary values to the database block's EGU
range. Ignores the most significant bit. No Alarming on Out of Range. |
15AL |
Scales 15-bit binary values to the database block's EGU
range. Ignores the most significant bit. Alarming on Out of Range. |
|
|