Target Systems, Inc. TS5000 Industrial Control Terminal (UT5)
OPC Server Data Sheet
Devices Supported: |
TS5000 Industrial Control Terminal |
Device
Manufacturer: |
Target Systems Inc. 3565 South West Temple,
Salt Lake City, UT 84115-4452. Voice: (801) 262-0651, Fax: (801) 262-0942. E-mail: info@holix.com. Contacts: Robert J. (Robyn) Reid, Edmund
H. Machen |
Profile Name: |
TS5000.PRO |
Profile Built For: |
UOS |
Platform: |
Windows NT4.0 / 2000 / XP |
Interface Type: |
Multidrop RS-485 two wire |
Max Devices
Supported: |
32 |
Protocol: |
TS5000 binary mode protocol with checksum |
Comment: |
UT5 is comprised of the Universal OPC
Server (UOS) for Serial and TCP/IP Devices and the TS5000.PRO device
profile. The UT5 mnemonic is used to identify this unique combination. UOS will also
support many other serial or TCP/IP device profiles. Please refer to our web site for the
current list. |
|
UOS is a stand-alone OPC Server that can be used with any OPC
compliant Client such as Intellutions FIX® or FIX Dynamics® or
OAs Enterprise Automation software. UOS has many advanced features like: DataView,
DataScope, Serial and TCP/IP communications support, and multiple "different"
device support. Please refer to our web site for more information on UOS capabilities. |
Contact: |
Dimension Software, Inc.
1536 St. Clair Road, Taylorsville, NC 28681, USA
Voice: (828) 635-7189, Fax: (828) 625-5319,
E-Mail: ,
Web: http://dimension-software.com |
References: |
UOS (Universal OPC Server) Electronic
Documentation |
|
TS 5000 Industrial Control Terminal
Users Manual, Section 17-Serial Commands |
|
Introduction
|
This document provides general information on the device commands supported by UOS and
the TS5000.PRO profile. If you have installed UOS, you should also review the sections
titled About the I/O Driver, How Do I
, Setting up The I/O Driver, and
Using the PowerTool in the UOS electronic documentation. To get there, click on Help
and Help Topics on the PowerTool menu bar. The PowerTool is a client application
with a graphical user interface that accesses the UOS OPC Server and lets you view and
modify communications channel, device, and datablock properties. |
|
Device Commands Supported
|
|
Short Commands |
A Axis |
|
R Measurements 1 - 7 |
|
V Version Information |
|
|
Long Commands; ?
(read) and S (write) where applicable |
25, 166, 31, 27, 26, 24, 95, 45, 134, 293, 294, 295, 135, 185, 191,
29, 30 |
Signal Conditioning
Name: |
Description: |
NONE |
No Scaling |
LIN (Unsigned) |
Scales 16-bit unsigned values to the database block's EGU
range. |
LIN (Signed) |
Scales 16-bit signed values to the database block's EGU
range. |
3BCD |
Scales 3-digit Binary Coded Decimal values to the database
block's EGU range. |
4BCD |
Scales 4-digit Binary Coded Decimal values to the database
block's EGU range. |
8BN |
Scales 8-bit binary values to the database block's EGU
range. Ignores the most significant byte. No Alarming on Out of Range. |
8AL |
Scales 8-bit binary values to the database block's EGU
range. Ignores the most significant byte. Alarming on Out of Range. |
12BN |
Scales 12-bit binary values to the database block's EGU
range. Ignores the most significant nibble (4-bits). No Alarming on Out of
Range. |
12AL |
Scales 12-bit binary values to the database block's EGU
range. Ignores the most significant nibble (4-bits). Alarming on Out of
Range. |
13BN |
Scales 13-bit binary values to the database block's EGU
range. Ignores the most significant 3 bits. No Alarming on Out of Range. |
13AL |
Scales 13-bit binary values to the database block's EGU
range. Ignores the most significant 3 bits. Alarming on Out of Range. |
15BN |
Scales 15-bit binary values to the database block's EGU
range. Ignores the most significant bit. No Alarming on Out of Range. |
15AL |
Scales 15-bit binary values to the database block's EGU
range. Ignores the most significant bit. Alarming on Out of Range. |
|
|